Joint selection

Hollow-Bore Robot Joint Actuators: Selection and Cable Routing

XTIVOR Robotics · · 6 min read

Choose a hollow-bore robot joint actuator by the usable cable passage, the complete motion cycle and the load on the axis. A central opening can help route wiring through a mechanism, but the connector, cable bends and moving assembly must all fit.

This guide compares XTIVOR's XTR-J113 and XTR-J114 and explains what to check before ordering a module for a custom robot wrist, end-effector assembly or articulated prototype. The intended joint position is a starting point for discussion, not proof that a module fits the task.

What a hollow bore helps you solve

Internal routing is worth considering when an external cable loop would interfere with nearby links, tools or covers. Potential uses include carrying gripper wiring, sensor leads or a compatible tube through an axis. Start with a sketch showing the fixed structure, rotating output, cable entry and cable exit.

The complete passage matters more than the opening visible in a product photo. Mounting adapters, output fittings and protective sleeves may reduce clearance. Ask which parts rotate and whether the usable passage remains clear after the module is installed. Explore the hollow-bore integration application page for the available hardware.

Compare XTR-J113 and XTR-J114

These are catalog specifications, not a guarantee of mechanical interchangeability. Dimensions retain the catalog's labels; use the installation drawings to orient them in your assembly.

Catalog specification XTR-J113 XTR-J114
Rated torque 4 N·m 2 N·m
Rated speed 50 rpm 40 rpm
Length and width 50 mm 44 mm
Height 53 mm 44.9 mm
Weight 385 g 237 g
Reduction ratio 31:1 31:1
Rated voltage 24 V 24 V
Communication CAN FD / CAN CAN FD / CAN
Indicative guide price USD 300+ Price on request
Usable through-bore clearance Confirm for supplied assembly Confirm for supplied assembly

J114 is the lighter option with smaller listed housing dimensions; J113 lists higher rated torque and speed. Those differences are useful for a shortlist, but neither table entry supplies the permissible cable bundle size or external bearing loads.

Review the J113 installation drawing and J114 installation drawing. Request confirmation of the clear passage for your selected revision before committing to a harness. Public guide prices are rounded planning estimates; exact and volume prices require a quotation.

Check the connector before the cable diameter

List every item that must pass through the assembly: cables, shields, sleeves, connectors and any tubing. For a pre-terminated harness, the largest connector can determine whether installation is possible even when the cable itself fits.

For example, a hypothetical 6 mm cable with a rigid 14 mm round connector cannot be threaded through a 12 mm circular opening. These are illustrative dimensions, not J113 or J114 specifications. Compare the actual connector envelope and its required insertion orientation with the full passage.

Also decide when the harness will be installed. If it must be routed before the output link is attached, check whether later cable replacement requires dismantling the mechanism. Confirm any connector removal or retermination with the harness supplier; do not assume it is permitted.

Plan bending, twisting and strain relief

A cable may bend at the entry, twist along the axis and bend again at the exit. Its suitability therefore depends on the motion and installation, not simply its electrical rating. igus describes robot cables designed for combined bending and torsion; use the chosen cable's own limits and test conditions rather than transferring another cable's rating to your design.

Record the maximum rotation in each direction, reversal frequency, unsupported cable length and locations where the harness is restrained. Reserve space for the specified bend radius and protection from sharp edges. Check the cable path throughout travel, including positions where it could rub, pinch or pull on a connector.

A prototype review should examine the harness as well as the actuator: connection stability, visible abrasion and changes in routing after repeated movements. Agree the test cycle and acceptance criteria for your application rather than assuming a universal service life.

Hollow bore does not mean unlimited rotation

A through-hole provides a routing path. It does not by itself provide a rotary electrical connection or prevent a cable from accumulating twist during repeated turns in the same direction.

Moog explains that slip rings transfer power or electrical signals between stationary and rotating structures. If continuous rotation is required, discuss the complete rotary-interface arrangement, including electrical channels, signal requirements and mechanical space. Do not assume a slip ring is included with either XTIVOR module. Likewise, routing a tube through a bore does not establish a rotary fluid connection.

Your routing requirement What to resolve before ordering
Limited back-and-forth rotation Cable torsion, bend radius, strain relief and full travel
Repeated turns in one direction A suitable rotary interface or another verified routing strategy
Pre-terminated camera or gripper cable Largest connector, passage clearance and assembly sequence
Several cables or a sleeved bundle Combined envelope, movement, separation and service access
Tubing through the axis Tube limits, fittings and whether a separate rotary connection is needed

Select torque for the whole moving assembly

Include the tool, workpiece, brackets and any downstream hardware in the load assessment. Specify their offsets from the axis, required acceleration, working poses and holding periods. Oriental Motor's sizing guidance treats inertia, torque and speed as related selection inputs.

Compare the required motion with each product's torque-speed information and confirm duty-cycle and thermal conditions. The catalog lists stall torque separately: 16 N·m for J113 and 10 N·m for J114. These values must not replace the rated torque figures when describing sustained operation. The rated-versus-stall torque guide explains the distinction.

Output torque also does not define allowable axial, radial or overturning loads. Send a load diagram and request the relevant limits, including whether the mechanism needs separate bearing support.

Verify the control interface and supplied configuration

Both modules list CAN FD / CAN, but that shared label does not establish plug-and-play software compatibility. Confirm the delivered connector pinout, command protocol, control modes, feedback and host-interface requirements. Use the CAN versus CAN FD checklist when preparing an integration request.

Keep the module's power and communication connections distinct from whatever you intend to route through the bore. Ask which cables, connectors and accessories are supplied, and which are project-specific additions. Avoid finalizing your enclosure from the bare module dimensions alone.

Send a complete hollow-joint inquiry

A useful request can fit on one page:

  • Task and axis: application, load, offsets and intended movement.
  • Routing: cable and connector dimensions, bundle count, sleeves and tubing.
  • Installation: available space, mounting arrangement and access for assembly or replacement.
  • Operating cycle: torque, speed, acceleration, travel limits and holding periods.
  • Controls and purchase: host controller, prototype quantity, expected volume and delivery destination.

Ask for the confirmed bore clearance, configuration, included accessories, exact price and lead time in the quotation. For a larger order, use the prototype-to-volume purchasing checklist to agree documentation and acceptance requirements.

Frequently asked questions

Can I determine the bore diameter from the housing width?

No. Housing dimensions do not establish the usable passage. Confirm the installed clear opening and any restrictions introduced by your mounting parts.

Does a hollow shaft guarantee continuous rotation with a camera cable?

No. Confirm the mechanical travel and the cable or rotary-interface arrangement together. A central opening alone does not prevent cable twist.

Can J113 replace J114 when I need more torque?

Not without reviewing the mounting, output interface, space, loads and controller configuration. Their listed dimensions and mass differ.

Discuss your routing plan with XTIVOR

Compare XTR-J113 and XTR-J114, then prepare a project inquiry. You can also email jennie@xtivor-robot.com with a routing sketch, load requirements and quantities for exact or wholesale pricing.

EXPLORE THE HARDWARE

Products in this guide